2) Press the ENTER key to open the LOG SETUP menu, then scroll UP or DOWN
to highlight either the TEMP1 or the TEMP2 menu depending on which of the
two Temperature Sensor Ports you want to make changes to.
Changing the Temperature Unit Value:
1) From within the SYSTEM menu, scroll UP or DOWN to highlight the LOG SETUP
menu.
3) Press the ENTER key to open the TEMP1 or TEMP2 menu. UNIT > ºF will be
highlighted.
4) Press the ENTER key, then scroll UP or DOWN to choose the desired Temperature
Unit value, either Fahrenheit or Celsius.
UNIT setting range is ºF and ºC. The default setting is ºF.

The TEMP1 and TEMP2 menus allow you to change the way Temperature information is displayed on the TELEMETRY screen
ALL and TEMP1 and/or TEMP2 pages, and when the Temperature Alert alarm sounds. For example, you can choose to display
Temperature values in either degrees Fahrenheit or degrees Celsius. In addition, the Maximum and Minimum Temperature values
can be adjusted to calibrate the TEMP1 and/or TEMP2 Indicator(s) on the TELEMETRY screen ALL page. You can also adjust the
Temperature value at which the Temperature Alert alarm will sound to suit the component the Temperature sensor is attached to.
This section covers both the TEMP1 and TEMP2 menus, since programming each of them is exactly the same. Choose either
the TEMP1 or the TEMP2 menu depending on which of the two Temperature Sensor Ports you want to make changes to.
Changing the Maximum Temperature Value:
The Maximum Temperature value determines the Maximum Temperature that will be displayed on the TELEMETRY screen
TEMP1 or TEMP2 page and also calibrates the TEMP1 or TEMP2 Indicator on the TELEMETRY screen ALL page.
The Maximum Temperature value cannot be set Lower than the Alert Temperature value or the Minimum Temperature value.
If necessary, you may need to Lower the Alert Temperature value prior to lowering the Maximum Temperature value.
1) From within the TEMP1 or TEMP2 menu, scroll UP or DOWN to highlight MAX
TEMP > 248ºF (or 120ºC).
2) Press the ENTER key, then scroll UP or DOWN to choose the desired Maximum
Temperature value.
MAX TEMP setting range is 68ºF to 302ºF (0ºC to 150ºC). The default setting is 248ºF (120ºC).
Changing the Alert Temperature Value:
The Alert Temperature value determines the temperature at which the Temperature Alert alarm will sound. For example, you can
set an Alert Temperature value for your nitro engine that will alert you when your engine's cylinder head temperature is getting too
hot. When the Alert Temperature value is reached, the Temperature Alert alarm will sound and LED2 will flash. The Temperature
Alert alarm will sound for approximately 5 seconds, however, LED2 will continue to flash until the temperature drops below the
Alert Temperature value. The audible portion of the Temperature Alert alarm can be cleared by pressing the BACK or ENTER keys.